Publikationen
Hämorrhagischer Schlaganfall

ACCERO®

2020

Poncyljusz, W. et al.
Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up
Journal of Clinical Medicine, 2020, 9, 2808
DOI: 10.3390/jcm9092808

Nania, A. et al.
Early experience treating intracranial aneurysms using Accero:
a novel, fully visible, low profile braided stent with platinum–nitinol composite wire technology
Journal of NeuroIntervent Surgery, 2020, 0, pp. 1–5
DOI: 10.1136/neurintsurg-2020-015918

Beuing, L. et al.
Stent-assisted coiling of broadnecked intracranial aneurysms with a new braided microstent (Accero):
procedural results and long-term follow-up
Scientific Reports 10.412 2020
DOI: 10.1038/s41598-019-57102-6

2019

Mühl-Benninghaus, R. et al.
Preclinical Evaluation of the Accero Stent:
Flow Remodelling Effect on Aneurysm, Vessel Reaction and Side Branch Patency
CardioVascular and Interventional Radiology, 2019, 42 (12), pp. 1786-1794
DOI: 10.1007/s00270-019-02345-z

ACCLINO® flex plus

2022

Melber, K. et al.
Long-term results of wide-necked intracranial bifurcation aneurysms treated with stent-assisted coiling using low-profile acandis acclino stents
Interventional Neuroradiology, 2022
DOI: 10.1177/15910199221121398

2021

Pflaeging, M. et al.
Treatment of recurrent and residual aneurysms with the low-profile Acandis Acclino stent:
Multi-center review of 19 patients
Journal of Clinical Neuroscience, 2021, 90, pp. 119-205
DOI: 10.1016/j.jocn.2021.05.051

Goertz, L. et al.
Low-Profile Laser-Cut Stents for Endovascular Treatment of Intracranial Aneurysms:
Incidence, Clinical Presentation and Risk Factors of Thromboembolic Events
Clinical Neuroradiology, 2021, 31 (1), pp. 107-115
DOI: 10.1007/s00062-019-00874-1

2020

Dietrich, Ph. et al.
Single Center Experience in Stent-Assisted Coiling of Complex Intracranial Aneurysms Using Low-Profile Stents
Clinical Neuroradiology, 2020
DOI: 10.1007/s00062-020-00883-5.

2019

Goertz, L. et al.
Long-term Angiographic Results of the Low-profile Acandis Acclino Stent for Treatment of Intracranial Aneurysms. A Multicenter Study
Clinical Neuroradiology, 2019
DOI: 10.1007/s00062-019-00847-4

2017

Brassel, F. et al.
Endovascular treatment of complex intracranial aneurysms using Acandis Acclino stents
Journal of NeuroInterventional Surgery, 2017, 9 (9), pp. 854–859
DOI: 10.1136/neurintsurg-2016-012571

2016

Tureli, D. et al.
Stent-assisted coil embolization of challenging intracranial aneurysms:
initial and mid-term results with low-profile ACCLINO devices
Acta neurochirurgica, 2016, 158 (8), pp. 1545–1553
DOI: 10.1007/s00701-016-2839-8

Brassel, F. et al.
Kissing-Y stenting for endovascular treatment of complex wide necked bifurcation aneurysms using Acandis Acclino stents: results and literature review
Journal of NeuroInterventional Surgery, 2016, 8 (4), pp. 386-395
DOI: 10.1136/neurintsurg-2015-011691

2015

Kabbasch, Ch. et al.
Initial Clinical Experience with a New Self-Expanding Nitinol Microstent for the Treatment of Wide-Neck Intracranial Cerebral Aneurysms: the Acandis Acclino Stent
Journal of Vascular and Interventional Neurology, 2015 (July), 8(3), pp. 1-6
PMCID: PMC4535594

DERIVO®

2023

Conan et al.
Effectiveness of Derivo Flow Diverter Device in the Endovascular Treatment of Cerebrovascular Aneurysms
Turk Neurosurg., 2022
DOI: 10.5137/1019-5149.JTN.40190-22.3

2022

Piñana, C. et al.
Derivo embolization device for intracranial aneurysms:
a Spanish multicenter retrospective study
Journal of Neurointerventional Surgergy, 2022
DOI: 10.1136/jnis-2022-019220

Thormann, M. et al.
The DERIVO® 2 Embolization Device in the treatment of ruptured and unruptured intracranial aneurysms:
A multicenter analysis
Interventional Neuroradiology, 2022
DOI: 10.1177/15910199221142643

Monteiro, A. et al.
A systematic review and meta-analysis of the Derivo Embolisation Device:
a novel surface-modified flow diverter for intracranial aneurysm treatment
Journal of NeuroInterventional Surgery, 2022
DOI: 10.1136/neurintsurg-2021-018390

2021

Mahajan, N.P. et al.
Retrospective Multicenter Indian Study of Derivo Embolization Device (REMIND):
Periprocedural Safety
Neurointervention, 2021 (August)
DOI: 10.5469/neuroint.2021.00227

Piano, M. et al.
Long-term follow-up of the DERIVO® Embolization Device (DeD®) for intracranial aneurysms:
the Italian Multicentric Registry
Journal of Neurosurgical Sciences, 2021, 65 (3), pp. 361-368
DOI: 10.23736/S0390-5616.21.05300-5

2020

Taschner, C.A. et al.
Derivo embolization device in the treatment of unruptured intracranial aneurysms:
a prospective multicenter study
Journal of NeuroInterventional Surgery, 2020, 0 pp. 1-6
DOI: 10.1136/neurintsurg-2020-016303

Akgul, E. et al.
Flow Diverter Stents in the Treatment of Cerebral Aneurysms Less than 5 mm
Turkish Neurosurgery, 2020 (March), 13, pp. 1-8
DOI: 10.5137/1019-5149.JTN.28762-19.2

2019

Akgul, E. et al.
The Derivo embolization device in the treatment of intracranial aneurysms:
short-and midterm results
World Neurosurgery, 2019 (November), 95, pp. 229-240
DOI: 10.1016/j.wneu.2016.07.101

Goertz, L. et al.
Improved Occlusion Rate of Intracranial Aneurysms Treated with the Derivo Embolization Device:
One-Year Clinical and Angiographic Follow-Up in a Multicenter Study
World Neurosurgery, 2019 (June), 126, pp. 1503-1509
DOI: 10.1016/j.wneu.2019.03.137

Goertz, L. et al.
Safety and efficacy of the Derivo Embolization Device for the treatment of ruptured intracranial aneurysms
Journal of NeuroInterventional Surgery, 2019, 11 (3), pp. 290-295
DOI: 10.1136/neurintsurg-2018-014166

Kraus, B. et al.
Safety and efficacy of the Derivo Embolization Device for the treatment of unruptured intracranial aneurysms:
a multicentric study
Journal of NeuroInterventional Surgery, 2019, 11 (1), pp. 68-73
DOI: 10.1136/neurintsurg-2018-013963

Trivelato, F.P. et al.
Derivo Embolization Device for the Treatment of Intracranial Aneurysms
Stroke, 2019, 50 (9), pp. 2351–2358
DOI: 10.1161/STROKEAHA.119.025407

Daglioglu, L. et al.
The Experience of the Derivo® Embolisation Device in Intracranial Aneurysms
Turkish Neurosurgery, 2019 (March), 27, pp. 1-8
DOI: 10.5137/1019-5149.JTN.25776-19.2

2018

Martínez-Galdámez, M. et al.
Internal Carotid Artery Reconstruction with a “Mega Flow Diverter”:
First Experience with the 6— 50 mm Derivo Embolization
Device Neurointervention, 2018 (September), 13, (2), pp. 133–137
DOI: 10.5469/neuroint.2018.00934

DERIVO® 2heal®

Goertz, L. et al.
First clinical experience with the Derivo 2heal embolization device for the treatment
of intracranial aneurysms
Interventional Neuroradiology, 2023, 19
DOI: 10.1177/15910199231193577

Publikationen
Ischämischer Schlaganfall

APERIO®/APERIO® Hybrid

2022

Goertz, L. et al.
Safety and Efficacy of the Novel Low-Profile APERIO Hybrid17 for a Treatment of Proximal and Distal Vessel Occlusion in Acute Ischemic Stroke: A Multi-Center Experience
World Neurosurg., 2022, 167, pp. e386-e396
DOI: 10.1016/j.wneu.2022.08.023

Weiss D. et al.
A fully radiopaque hybrid stent retriever versus a precursor device:
Outcome, efficacy, and safety in large vessel stroke

Journal of Neuroimaging, 2022 (September), 32(5), pp. 947-955
DOI: 10.1111/jon.12999

Vogt M. et al.
Safety and Effectiveness of the New Generation APERIO® Hybrid Stent-retriever Device in Large Vessel Occlusion Stroke
Clinical Neuroradiology, 2022, 32, pp. 141–151
DOI: 10.1007/s00062-021-01122-1

2020

Kaschner, M. et al.
The new fully radiopaque Aperio Hybrid stent retrieber:
Efficient and safe? An early Multicenter Experience

World Neurosurgery, 2020 (September), 141, pp. e278-e288
DOI: 10.1016/j.wneu.2020.05.104

2019

Kaschner, M. et al.
One-year singel-center experience with the Aperio thrombectomy device in large vessel occlusion in the anterior circulation: safety, efficacy, and clinical outcome
NeuroSurgical Sciences, 2019, 40 (7), pp. 1443-1451
DOI: 10.1007/s10072-019-03861-z

Müller-Eschner, M. et al.
Introducing the New 3.5/28 Microstent Retriever for Recanalization of Distal Cerebral Arteries in Acute Stroke:
Preliminary Results

CardioVascular and Interventional Radiology, 2019, 42 (1), pp.101-109
DOI: 10.1007/s00270-018-2039-4

2016

Kallenberg, K. et al.
Endovascular stroke therapy with the Aperio thrombectomy device
Journal of NeuroInterventional Surgery, 2016 (July), 8, pp. 834-839
DOI: 10.1136/neurintsurg-2015-011678

2012

Rot, C. et al.
A comparison of 2 stroke devices:
the new Aperio clot-removal device and the solitaire AB/FR

American Journal of Neuroradiology, 2012, 33 (7), pp. 1317-1320
DOI: 10.3174/ajnr.A2962

Saleh, M. et al.
Safety and efficacy of the Aperio thrombectomy device when compared to the Solitaire AB/FR and the Revive devices in a pulsatile flow system
American Journal of Cardiovascular Disease, 2012, 2(4), pp. 301-8
PMCID: PMC3499937

CREDO®

2021

Francesco, D. et al.
Watershed subarachnoid hemorrhage after middle cerebral artery rescue stenting in patients with acute ischemic stroke
Neuroradiology, 2021, 63 (8), pp.1383-1388
DOI: 10.1007/s00234-021-02692-0

2020

Lukas, M. et al.
Intracranial Stenting After Failed Thrombectomy in Patients With Moderately Severe Stroke. A Multicenter Cohort Study
Frontiers in Neurology, 2020
DOI: 10.3389/fneur.2020.00097

2019

Nordmeyer, H. et al.
Endovascular Treatment of Intracranial Atherosclerotic Stenosis
Georg Thieme Verlag Fortschr Röntgenstr, 2019
DOI: 10.1055/a0855-4298

2018

Forbrig, R. et al.
Intracranial Rescue Stent Angioplasty After Stent-Retriever Thrombectomy
Clinical Neuroradiology Springer 2018
DOI: 10.1007/s00062-018-0690-4

Nordmeyer, H. et al.
Angioplasty and Stenting of Intracranial Arterial Stenosis in Perforator-Bearing Segments:
A Comparison Between the Anterior and the Posterior Circulation

Frontiers in Neurology, 2018, 9:533
DOI: 10.3389/fneur.2018.00533

2016

Möhlenbruch, M. et al.
One-pass endovascular treatment of intracranial atherosclerotic stenosis with a novel PTA balloon and self-expanding microstent
Springer Neuroradiology, 2016
DOI: 10.1007/s00234-016-1716-8

ACCLINO®/ACCLINO® flex plus

2020

Meyer, L. et al.
Intracranial Stenting After Failed Thrombectomy in Patients With Moderately Severe Stroke:
A Multicenter Cohort Study

Frontiers in neurology 2002 (Feb), 14 
DOI: 10.3389/fneur.2020.00097

Meyer, L. et al.
Stenting with Acclino (flex) for symptomatic intracranial stenosis as secondary stroke prevention
Journal of NeuroInterventional Surgery 2020, 12(11), pp. 1127-1131
DOI: 10.1136/neurintsurg-2019-015744

Stracke, Ch. et al.
Intracranial bailout stenting with the Acclino (Flex) Stent/NeuroSpeed Balloon Catheter after failed thrombectomy in acute ischemic stroke: a multicenter experience
Journal of NeuroInterventional Surgery 2020, 12 (1), pp. 43-47
DOI: 10.1136/neurintsurg-2019-014957

Publikationen
HEAL Technology

HEAL Technology

2024

Girbas, M. et al.
Comparison of the hemocompatibility of neurovascular flow diverters with antithrombogenic coatings
Journal of Science: Advanced Materials and Devices, 2024 (March), Volume 9 Issue 1
DOI: 10.1016/j.jsamd.2023.100666

2022

Mühl-Benningshaus, R. et al.
Vascular Response on a Novel Fibrin-Based Coated Flow Diverter
Labratory Investigation, Stroke/Neurointerventions, 2022, Volume 45; pp. 236 - 243
DOI: 10.1007/s00270-021-03007-9

2020

Link, A. et al.
In vitro investigation of an intracranial flow diverter with a fibrin-based, hemostasis mimicking, nanocoating
Biomedical Materials, 2020, Volume 16, Number 1
DOI: 10.1088/1748-605X/abc8d3

2017

Kaplan, O. et al.
Low-thrombogenic fibrin-heparin coating promotes in vitro endothelialization
Journal of Biomedical Materials Research, 2017 (November) Volume 105, Issue 11; pp. 2995 - 3005
DOI: 10.1016/j.jsamd.2023.100666