APERIO® Hybrid Thrombectomy Device

The new highly visible Nitinol stent retriever for fast flow restoration

The APERIO® Hybrid Thrombectomy Device is the third generation of Acandis® stent retriever featuring a perfect interplay in acute ischaemic strokes:

  • Outstanding visibility for maximum control and safety
  • Effective hybrid cell design for fast flow restoration
  • Broad range of sizes for tailored treatment options


 

RELIABLE

The proven hybrid cell design leads to reliable and fast flow restoration. Small closed cells ensure a perfect vessel wall apposition and expansion into the clot. Large open cells with integrated anchoring elements assure efficient clot retention for reliable and atraumatic retrieval even in tortuous vessel anatomies. In combination, these two cell designs build up a functional segment.

APERIO hybrid functional segments

Functional segment of the APERIO® Hybrid Thrombectomy Device

APERIO hybrid functional segments

APERIO® Hybrid Thrombectomy Device (6.0 x 50 mm) – functional segments

 


 

HIGHLY VISIBLE

Depiction of Aperio Hybrid


 

VARIABLE

The broad range of sizes enables the treatment of vessel diameters from 1.5 mm up to 5.5 mm. All sizes are suitable with 0.021‘‘ microcatheter. Due to repeating functional segments the device working length can be adapted.


 

SAFE

Thanks to the proven hybrid cell design and the excellent full length visibility, the APERIO® Hybrid Thrombectomy Device leads to a maximum in safety and reliability during the procedure.


 

EFFICIENT

The constant and balanced radial force over the intended vessel diameter allows a gentle and highly efficient clot removal.1

1      Machi P, Jourdan F, Ambard D, et al Experimental evaluation of stent retrievers’ mechanical properties and effectiveness, Journal of NeuroInterventional Surgery 2017;9:257-263.

Aperio Pre Treatment

Pre treatment
Total occlusion of middle cerebral artery

Aperio Treatment

Treatment
with APERIO® Hybrid Thrombectomy Device 4.5 x 30 mm

Aperio Post Treatment

Post treatment
Final result after first pass

 

Images are courtesy of Dr. Christoph Kabbasch, University Hospital Cologne, Germany


 

ORDERING INFORMATION

 

Labelled
APERIO® Hybrid
Dimensions (mm)

Reference
Number

Device
Diameter
(mm)

Device
Length *
(mm)

Recommended
Vessel Diameter
(mm)

Required Microcatheters for Delivery (Inch)

3.5 x 28

01-000704

3.5

28

1.5 - 3.0

0.021

4.5 x 30

01-000705

4.5

30

2.0 - 4.0

0.021

4.5 x 40

01-000706

4.5

40

2.0 - 4.0

0.021

4.5 x 50

01-000707

4.5

50

2.0 - 4.0

0.021

6.0 x 40

01-000708

6.0

40

3.5 - 5.5

0.021 - 0.027

6.0 x 50

01-000709

6.0

50

3.5 - 5.5

0.021 - 0.027


* Average length within intended vessel diameter

 

Recommended Microcatheters

 

Product Name

Reference
Number

ID
(Inch)

OD dist./prox.
(French)

Usable Length
(cm)

Tip Shape

NeuroSlider® 21

01-000273

0.021

2.4 / 2.5

155

Straight

NeuroSlider® 27

01-000274

0.027

3.0 / 3.1

155

Straight

 

Recommended Intermediate Catheters

 

Product name

Reference Number

ID
(Inch)

OD dist./ ODprox.
(French / Inch)

Usable / Total Length
(cm)

Tip Shape

NeuroBridge® 52

01-000518

0,052

5,0 / 0,066
5,3 / 0,070

105 / 111

Multi-Purpose 25°

NeuroBridge® 52

01-000511

0,052

5,0 / 0,066
5,3 / 0,070

115 / 121

Multi-Purpose 25°

NeuroBridge® 52

01-000512

0,052

5,0 / 0,066
5,3 / 0,070

125 / 131

Multi-Purpose 25°

NeuroBridge® 52

01-000513

0,052

5,0 / 0,066
5,3 / 0,070

135 / 141

Multi-Purpose 25°

NeuroBridge® 65

01-000519

0,065

6,1 / 0,080
6,3 / 0,083

105 / 111

Multi-Purpose 25°

NeuroBridge® 65

01-000514

0,065

6,1 / 0,080
6,3 / 0,083

115 / 121

Multi-Purpose 25°

NeuroBridge® 65

01-000515

0,065

6,1 / 0,080
6,3 / 0,083

125 / 131

Multi-Purpose 25°