DERIVO® and DERIVO® mini Embolisation Device

Advanced flow diversion with unique visibility concept

The flow diversion technique with the use of embolisation devices placed in the parent artery is a new approach to treat intracranial aneurysms – especially fusiform and wide neck aneurysms.

These devices have a high vessel wall coverage and the ability to change haemodynamic forces and vectors in the segment bearing the aneurysm.

 

The DERIVO® and DERIVO® mini Embolisation Device are Acandis’® reliable and effective flow diverter featuring proven technology and additional service:

  • Unique X-ray visibility
  • Perfect vessel wall adaptability
  • Broad range of sizes for tailored treatment options
  • True self-expansion
  • Resheathability
  • 3D Sizing Simulation

 

VISIBLE

The entire contour and shape of the DERIVO® and DERIVO® mini Embolisation Device are perfectly visible due to Platinum-Nitinol composite wires. Three addiational Platinum-Iridium X-ray markers on both ends allow accurate placement and permanent control.

 

Treatment of left saccular ICA aneurysm with DERIVO® Embolisation Device 5.0 mm x 20 mm

derivo img 01

Excellent visibility of DERIVO® contour even in front of dense bone strucutres. View inside the lumen is possible.

derivo img 02

Opening of DERIVO® in tight curve is clearly visible.

 

Images are courtesy by Prof. Dr. Wolfgang Reith, University Hospital Saarland (Homburg), Germany


 

ADAPTIVE

Outstanding flexibility, based on special braiding properties, combined with well-balanced radial force lead to perfect adaptability of the DERIVO® and DERIVO® mini Embolisation Device.

 

Treatment of large right ICA aneurysm with DERIVO® Embolisation Device 4.0 mm x 30 mm

derivo img 03

Perfect wall apposition: DERIVO® contour follows exactly the tortous shape of the vessel.

derivo img 04

Immediate flow diversion effect after DERIVO® placement.

derivo img 05

Excellent visibility of fully released DERIVO®.

 

Images are courtesy by Dr. Sascha Prothmann, Klinikum rechts der Isar, Technical University Munich, Germany


 

BROADEST RANGE

 

DERIVO® Embolisation Device

DERIVO® mini Embolisation Device

Vessel Diameter

2.5 mm - 6.0 mm

1.5 mm - 3.5 mm

Device Length

15 mm - 50 mm*

15 mm - 25 mm

Required Microcatheter for Delivery

0.027’’ ID

0.021’’ ID

Recommended Microcatheter for Delivery

NeuroSlider® 27

NeuroSlider® 21 DLC


*Long leasions can be treated by a single DERIVO® Embolisation Device (no telescoping with several devices necessary)


 

SAFETY & EFFICACY

Acandis® offers an unique sizing support in preparation of cases with the DERIVO® & DERIVO® mini Embolisation Device.
By the Acandis’ 3D sizing simulation based on the Ankyras Software, we assist physicians to choose the optimal device dimensions prior to treatment.

For more information about our Training & Service click here


 

EXCELLENT CLINICAL PERFORMANCE

  • Secure wall apposition as a result of flared ends and closed distal ends
  • Improved corrosion resistance and lower thrombogenicity1 due to BlueXide® surface finishing
  • Outstanding flexibility combined with well-balanced radial force

1 results from in-vitro testings


 