APERIO® Thrombectomy Device

Reliable Nitinol stent retriever for fast flow restoration

The APERIO® Thrombectomy Device is the second generation of the reliable Acandis® stent retriever, which shows perfect interplay in acute ischaemic strokes:

  • Perfect vessel wall apposition
  • Featuring a hybrid cell-design
  • Improved expansion into the clot
  • Efficient and secure clot retention


 

Hybrid Cell Design

The APERIO® Thrombectomy Device features a hybrid cell  design. The small closed cells ensure a good vessel wall apposition and improved expansion into the clot. The large open cells with integrated anchoring elements are designed to assure efficient clot retention

Acandis GmbH: APERIO in the eye

Functional Segment


 

Extended range

With its extended range the APERIO® Thrombectomy Device is suitable for vessel diameters from 1.5 mm to 5.5 mm.

Aperio RangeVarious sizes for tailored treatment

 
 

Ordering Information

 

Labelled
APERIO®
Dimensions (mm)

Reference
Number

Device
Diameter
(mm)

Device
Length
(mm)

Recommended
Vessel Diameter
(mm)

Compatible Microcatheters for Delivery (Inch)

3.5 x 28

01-000700

3.5

28

1.5 - 3.0

0.0165 - 0.021

4.5 x 30

01-000701

4.5

30

2.0 - 4.0

0.0165 - 0.021

4.5 x 40

01-000702

4.5

40

2.0 - 4.0

0.021 - 0.027

6.0 x 40

01-000703

6.0

40

3.5 - 5.5

0.021 - 0.027

 

Enhanced microcather compatibility

The enhanced compatibility of the APERIO® with smaller microcatheters allows for an increased aspiration lumen and easier thrombus passage. Moreover, all devices are compatible with 0.021" ID microcatheters, meaning that there is no need to exchange the microcatheter if a different size of the device is choosen during the procedure.

The APERIO® Thrombectomy Device is compatible with the Acandis® - NeuroSlider® Microcatheter and NeuroBridge® Intermediate Catheter.

 

APERIO NeuroSlider

Tab. 1: Increase of aspiration lumen

 
 

Recommended Microcatheters

 

Product Name

Reference
Number*

ID
(Inch)

OD dist./prox.
(French)

Usable Length
(cm)

NeuroSlider® 17

01-000272

0.0165

1.9 / 2.1

155

NeuroSlider® 21

01-000273

0.021

2.4 / 2.5

155

NeuroSlider® 27

01-000274

0.027

3.0 / 3.6

155


*For availability please contact your local representative from Acandis.

 

RELIABLE

  • Good vessel wall apposition and clot integration due to effective hybrid cell design

VARIABLE

  • Enhanced compatibility with smaller microcatheters
  • Adaptable device working length

SAFE

  • Optimal safety during procedure thanks to improved design
  • Easy and clear radiopaque marker concept

 

The APERIO® Thrombectomy Device is not available within the territory of the United States.

 